Intelligent key and asset management.
Inactive leaf door hardware.
The active leaf is the leaf upon which the locking hardware is installed and is used most often.
A set of double doors consists of two door leaves installed in a single frame.
We identify each leaf as either active or inactive to help with the installation of hardware as well as to help with prepping and reinforcing the frame and the doors as needed so they function properly.
The other leaf is considered inactive and remains locked the majority of the time.
The only approved latching hardware for inactive leaf of pairs w.
Inactive leaf locking system.
Be used on the inactive leaf that is flush surface bolted or with a surface or concealed vertical rod device on other door leaf.
One leaf is considered active and can be opened and closed using a knob or lever.
Since there are two doors in a pair there are two leaves in a double door opening.
Since the inactive leaf doesn t automatically latch when it closes i think a closer could almost be detrimental here as the door could be closed and presumed latched even though.
Other door hardware used on the opening must be compatible with the type of flush bolts you use.
In this application the active leaf would typically have a lockset which latches into a strike mounted on the edge of the inactive leaf.
Double doors typically have an active leaf and and inactive leaf.
Inactive door wde inactive.
Bottom rod guide n5150.
Active door leaf vs.
My cor is not allowing my inactive leaf with push side overlapping astragal to close first.
When the inactive leaf is closed the lever can be moved to thedownposition projecting the bolt into the strike and securely locking the inactive leaf.
Flush bolts are installed into the lock stile on the inactive leaf of a pair of doors there are often two bolts one installed at the top and one at the bottom of the door the strike of the top bolt will be in the head of the frame and the strike for the bottom bolt will be in the floor.
The next question is whether the inactive leaf of a pair of fire doors leading to a room that is not normally occupied by humans is required to have a door closer.
Flush bolts are used to secure the inactive leaf of a pair of doors projecting into the frame head and into a floor strike.
Door strength and rigidity maintained by tying door faces to reinforcing extensions on guide.
The only approved latching hardware for inactive leaf of pairs w.
Sliding and folding door hardware.
What is the definition of double egress.
Inactive leaf locking system.